Skip to content

Electrical engineering.At the speed of thought.

Designstrom brings electrical design, fault detection, verification and PLC engineering into one connected workspace, on a structured engineering model that AI can work with.

Star-delta pump P1 1 error 4 warnings
Control circuits of a star-delta starter with the missing interlock marked
The engine's own output on the star-delta example project, not a mock-up.

From a description to a checked drawing set.

Real screens from Designstrom, on a twelve-page conveyor panel project.

  1. Describe the job

    Start a project with a few sentences and the documents you already have: sketches, old drawings, datasheets.

  2. The Designer drafts and edits

    The AI assistant turns the request into edit operations on the model: pages, devices, wires. Ask for a change, and it makes it.

  3. Every part is engineering data

    Select a symbol to see what it is: tag, function, location, and every pin with its wire and connections.

  4. Checked as you go

    Each finding sits on the part it concerns, with the clause behind it and, where it can be expressed exactly, a one-click fix.

The engineering lives in the drawings.
The checking is still done by hand.

  • Repetitive schematicsThe same starter, the same terminal strip, drawn again for every machine.
  • Slow modificationsOne change ripples through pages, references and terminal plans.
  • Design and PLC apartI/O lists and tag tables retyped from the drawings into the PLC project.
  • Manual error checkingInterlocks, earth conductors and coil voltages checked by eye.
  • Knowledge in peopleThe rules sit in drawings and in a few senior engineers.
  • Late reworkMistakes found at the panel or at commissioning cost the most to fix.

An engineering model underneath every drawing.

Designstrom does not treat a schematic as pixels or loose lines. Components, pins, wires and potentials are engineering entities in one model. Deterministic engineering logic checks it, and the AI assistant works on the same model. Point at a part to find it on the sheet.

A drawing

The star coil circuit as lines and symbols

Lines, symbols and manual interpretation.

The same drawing in Designstrom

The star coil circuit as drawn by the engine
  - id: ctrl-star
    page: control
    from: L1
    to: "N"
    path:
      - { F3: 1>2 }
      - { KT1: 15>16 }
      - { KM2: 21>22 }
      - { KM3: coil }
Net at KM3:A1
KM2:22 · KM3:A1
Interlock
-KM2 21-22 opens this coil while -KM2 (delta) is closed

Visual design, a structured model and engineering logic, together.

A different starting point.

Traditional workflowThe Designstrom approach
Manual-first designAI-assisted design
Drawing-centricA structured engineering model
Separate validation stepsAn integrated validation loop
Repetitive manual changesConversational iteration
Schematic and PLC work apartOne connected workflow

AI accelerates engineering.
Engineering rules still matter.

The assistant and the engine each do what they are best at, with one structured model between them.

  1. Input

    Your description, sketches and datasheets.

  2. The assistant

    AI assistance

    The Designer proposes edit operations you can review and undo.

  3. Structured model

    Components, pins, wires and potentials in one readable file.

  4. The engine

    Deterministic verification

    50 kinds of finding, each with the rule behind it.

  5. Output

    Drawing set, BOM, wire lists and PLC tag tables.

The engineer reviews every change and approves the deliverables.

Generate. Validate. Correct. Verify. Deliver.

One engineering loop on one model, shown here on a real drawing: a star-delta starter with a missing interlock, taken from first findings to a verified drawing set.

Validate

The engine checks the whole netlist on every change and marks each finding on the part it concerns.

1 error 4 warnings
  • W-NO-MAIN-SWITCHThe supply (L1 L2 L3) has no main disconnecting device: Q1, KM1, KT1, F2 connect to it directlyIEC 60204-1 §5.3Fix
  • E-INTERLOCK-MISSINGKM2 and KM3 short L1–L2, L1–L3, L2–L3 when both close, and KM3's coil does not pass an NC contact of KM2IEC 60204-1 §9.3.4, §9.3.5Fix
  • W-NO-PROTECTIONKM2.coil is fed from the mains through KT1.c2 → KM3.aux2 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
  • W-NO-PROTECTIONKM3.coil is fed from the mains through KT1.c1 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
  • W-NO-PROTECTIONKT1.coil is fed from the mains through KM1.aux2 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
The control circuit with its findings marked

Every stage is the engine's own output for the control page of the star-delta example project.

One workspace, from schematic to PLC.

The drawing you edit is the netlist the engine checks, the model the assistant works on, and the source of every list and tag table.

  • Electrical design

    A full 2D schematic editor in the browser. Place IEC 60617 symbols, draw wires pin to pin, manage pages, title blocks and paper sizes. Every symbol and wire is an engineering entity, not a line on a canvas.

    IEC 60617 symbols · pages, title blocks, paper sizes · undo on every edit

  • AI engineering assistant

    Describe a circuit, or a change to one, in plain language, and attach the documents behind it. The assistant answers with edit operations on the model, which you review, apply or undo like any edit. Everything it proposes is verified by the same engineering checks.

    Plain language · attached documents · reviewable edit operations

  • Fault detection and verification

    50 kinds of finding across electrical, PLC, network and machine-safety rules, each on the part it concerns with the rule behind it. Change, re-check, repeat.

    Checks cover defined rules only, and verification scope varies by rule and configuration. Not a certification or a claim of full compliance.

    Electrical · PLC · network · machine safety

  • PLC engineering

    Rack, addresses, I/O list and tags come from the same design, so the PLC project starts where the schematic ends. Tag tables for Siemens TIA Portal, Rockwell Studio 5000, IEC 61131-3 (Codesys, TwinCAT), Schneider Electric, Omron Sysmac / CX-Programmer, Mitsubishi GX Works.

    PLC logic generated from the design: In development with design partners

    Rack · addresses · I/O list · six tag-table formats

  • Documentation

    The PDF drawing set, BOM, wire list, terminal plan and cable list all come from the same model, so they always agree.

    PDF · XLSX · CSV

Built on the standards you already work to.

Symbols, sheets, designations and checks follow the IEC and ISO conventions of the trade.

Drawings follow
StandardUsed for
IEC 60617Graphical symbols on every sheet
IEC 61082-1Sheet frame, current-path columns and page.column cross-references
IEC 81346Reference designations: =function +location -tag
EN ISO 7200Title blocks
IEC 60445 · IEC 60757Conductor colours and colour codes on wires
IEC 61131-3PLC tag names, data types and the generic tag table
Designs are checked against
StandardUsed for
IEC 60204-1Main switch, protection, motor overload, protective earth, emergency stop, interlocks, coil switching and wire colours
ISO 13850Emergency stop wired in hardware
IEC 60364-5-54Protective conductor cross-sections
IEC 60364-5-52Wire cross-section against the protective device
IEC 61140Which equipment needs protective earth

For the panels and machines you build.

ApplicationWhat the engine checks thereExample project in the editor
Industrial control panelsMain switch, protection, PE sizes, terminal fillEvery example project
Motor control systemsInterlocks, overloads, coil voltages, wire coloursDOL starter conveyor M17 pages · 9 devicesStar-delta pump P12 pages · 9 devices
Conveyor systemsPLC inputs, PNP/NPN, a hardwired emergency stopConveyor drive M1 — PLC controlled DOL starter11 pages · 16 devices
Machine automationRack slots, addresses, tag names per vendorConveyor 3 PLC6 pages · 10 devicesMixer 2 PLC2 pages · 5 devices
Process automationAnalog signal ranges between devices and PLC channelsNo example project yet
Networked machine cellsIP addresses, PROFINET names, EtherCAT port orderPackaging cell PROFINET3 pages · 5 devicesAssembly line EtherCAT2 pages · 3 devices
Repetitive machine designsThe same checks on every variant of one readable project fileEvery example project

Help shape the future of electrical engineering.

Designstrom is collaborating with a select group of teams who design and build electrical systems:

Who we work with

  • Industrial automation system integrators
  • Electrical panel builders
  • Machine manufacturers and OEMs
  • Electrical engineering teams

Design partners receive

  • Early access to the product
  • Direct collaboration with the founder
  • Implementation and onboarding support
  • The opportunity to influence the product roadmap
  • Validation on your real engineering workflows

We'll reply within 2 working days. Your details are used only to reply.

Prefer to talk first? Book a product walkthrough →

Portrait of Aradhya Saxena

Built by someone who understands both sides of engineering.

Aradhya Saxena spent 3.5 years as a system integration engineer (industrial automation, schematics, machine systems), then 5 years in software and agentic AI. Designstrom is the tool he wanted on the shop floor.

LinkedIn · Aradhya Saxena

Questions engineers ask.

Does Designstrom replace my CAD tool?

Designstrom is a model-first workspace for schematic design. Start with new projects or variants, side by side with the tools you use today.

Does the AI decide whether a design is correct?

The Designstrom engine checks the design deterministically. The AI reviews the layout, proposes and edits, and the engineer approves.

What does a passing check mean for my design?

Checks cover defined rules and standards, which makes your design review-ready.

Which standards do you use?

IEC 60617 symbols, and rule checks drawn from IEC 60204-1, ISO 13850, IEC 60364-5-54 and IEC 61140. PLC tag naming follows IEC 61131-3.

Which PLC platforms can I export tag tables for?

Siemens TIA Portal, Rockwell Studio 5000, IEC 61131-3 (CODESYS, TwinCAT), Schneider Electric, Omron Sysmac / CX-Programmer and Mitsubishi GX Works.

Can it generate PLC logic?

PLC logic generation is in development with our design partners. Today Designstrom already builds the rack, addresses, I/O list and tag tables from your design.

Is it available in German?

Yes, the interface supports English and German.

What happens to my project data?

Your project data stays yours and is used only with your permission.

Your next design shouldn't start from scratch.

Bring us a real electrical engineering workflow. Let's explore what Designstrom can accelerate.