Electrical engineering.At the speed of thought.
Designstrom brings electrical design, fault detection, verification and PLC engineering into one connected workspace, on a structured engineering model that AI can work with.
From a description to a checked drawing set.
Real screens from Designstrom, on a twelve-page conveyor panel project.
Describe the job
Start a project with a few sentences and the documents you already have: sketches, old drawings, datasheets.

The Designer drafts and edits
The AI assistant turns the request into edit operations on the model: pages, devices, wires. Ask for a change, and it makes it.

Every part is engineering data
Select a symbol to see what it is: tag, function, location, and every pin with its wire and connections.

Checked as you go
Each finding sits on the part it concerns, with the clause behind it and, where it can be expressed exactly, a one-click fix.

The engineering lives in the drawings.
The checking is still done by hand.
- Repetitive schematicsThe same starter, the same terminal strip, drawn again for every machine.
- Slow modificationsOne change ripples through pages, references and terminal plans.
- Design and PLC apartI/O lists and tag tables retyped from the drawings into the PLC project.
- Manual error checkingInterlocks, earth conductors and coil voltages checked by eye.
- Knowledge in peopleThe rules sit in drawings and in a few senior engineers.
- Late reworkMistakes found at the panel or at commissioning cost the most to fix.
An engineering model underneath every drawing.
Designstrom does not treat a schematic as pixels or loose lines. Components, pins, wires and potentials are engineering entities in one model. Deterministic engineering logic checks it, and the AI assistant works on the same model. Point at a part to find it on the sheet.
A drawing
Lines, symbols and manual interpretation.
The same drawing in Designstrom
- id: ctrl-star
page: control
from: L1
to: "N"
path:
- { F3: 1>2 }
- { KT1: 15>16 }
- { KM2: 21>22 }
- { KM3: coil }- Net at KM3:A1
- KM2:22 · KM3:A1
- Interlock
- -KM2 21-22 opens this coil while -KM2 (delta) is closed
Visual design, a structured model and engineering logic, together.
A different starting point.
| Traditional workflow | The Designstrom approach |
|---|---|
| Manual-first design | AI-assisted design |
| Drawing-centric | A structured engineering model |
| Separate validation steps | An integrated validation loop |
| Repetitive manual changes | Conversational iteration |
| Schematic and PLC work apart | One connected workflow |
AI accelerates engineering.
Engineering rules still matter.
The assistant and the engine each do what they are best at, with one structured model between them.
Input
Your description, sketches and datasheets.
- The assistant
AI assistance
The Designer proposes edit operations you can review and undo.
Structured model
Components, pins, wires and potentials in one readable file.
- The engine
Deterministic verification
50 kinds of finding, each with the rule behind it.
Output
Drawing set, BOM, wire lists and PLC tag tables.
Generate. Validate. Correct. Verify. Deliver.
One engineering loop on one model, shown here on a real drawing: a star-delta starter with a missing interlock, taken from first findings to a verified drawing set.
Generate
Start from engineering intent: draw in the editor, or describe the circuit to the assistant. Either way the design lands in one structured model, drawn as IEC sheets.
- id: ctrl-star
page: control
from: L1
to: N
path:
- KT1: 15>16
- KM3: coil9 devices · 23 nets · 2 pages
Validate
The engine checks the whole netlist on every change and marks each finding on the part it concerns.
1 error 4 warnings- W-NO-MAIN-SWITCHThe supply (L1 L2 L3) has no main disconnecting device: Q1, KM1, KT1, F2 connect to it directlyIEC 60204-1 §5.3Fix
- E-INTERLOCK-MISSINGKM2 and KM3 short L1–L2, L1–L3, L2–L3 when both close, and KM3's coil does not pass an NC contact of KM2IEC 60204-1 §9.3.4, §9.3.5Fix
- W-NO-PROTECTIONKM2.coil is fed from the mains through KT1.c2 → KM3.aux2 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
- W-NO-PROTECTIONKM3.coil is fed from the mains through KT1.c1 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
- W-NO-PROTECTIONKT1.coil is fed from the mains through KM1.aux2 with no fuse or circuit breaker ahead of itIEC 60204-1 §7.2Fix
Correct
Every fix is a set of edit operations on the model: readable, reviewable and undoable. Apply them in the editor, or let the assistant propose them.
- Interlock: KM2 NC in KM3's coil circuit
- Add main switch Q0 (switch-disconnector, 3 poles) feeding L1 L2 L3
- Add circuit breaker F1 at the start of circuit ctrl-delta
- Add circuit breaker F3 at the start of circuit ctrl-star
- Add circuit breaker F4 at the start of circuit ctrl-timer
Verify
The same checks run again at once. Machine safety reads as a checklist against IEC 60204-1.
0 errors 0 warnings- Emergency stop: positively opened NC contacts that de-energize actuators by hardwire
- Contactors that short the supply when closed together are interlocked
- Coils connect directly to the earthed return; contacts switch the line side
- Every load fed from the mains has a fuse or circuit breaker ahead of it
- The mains supply has a disconnecting device (main switch) ahead of everything else
- Motors above 0.5 kW have overload protection
- Protective conductors are not smaller than the phase conductors require
- Emergency stop: every motor contactor and drive enable drops out when it is pressed
- Indication and fault signalling stays powered when the emergency stop is pressed
Deliver
The drawing set and its downstream documents come from the same model, so they cannot drift apart.
- PDF drawing set2 sheets, title block, page.column references
- Bill of materials10 positions, XLSX / CSV
- Wire list46 conductors with numbers and cross-sections
- Project fileone readable .ehy document, diffable and scriptable
Bill of materials · Star-delta pump P1
| Pos | Qty | Tags | Part | Description |
|---|---|---|---|---|
| 1 | 3 | -F1, -F3, -F4 | Miniature circuit breaker | |
| 2 | 1 | -F2 | iC60N-C2-1P | MCB 1P C2 |
| 3 | 2 | -KM1, -KM2 | LC1D25P7 | Contactor 25 A AC-3 |
| 4 | 1 | -KM3 | LC1D18P7 | Contactor 18 A AC-3 |
| 5 | 1 | -KT1 | RE17RAMU | On-delay timer |
Every stage is the engine's own output for the control page of the star-delta example project.
One workspace, from schematic to PLC.
The drawing you edit is the netlist the engine checks, the model the assistant works on, and the source of every list and tag table.
Electrical design
A full 2D schematic editor in the browser. Place IEC 60617 symbols, draw wires pin to pin, manage pages, title blocks and paper sizes. Every symbol and wire is an engineering entity, not a line on a canvas.
IEC 60617 symbols · pages, title blocks, paper sizes · undo on every edit
AI engineering assistant
Describe a circuit, or a change to one, in plain language, and attach the documents behind it. The assistant answers with edit operations on the model, which you review, apply or undo like any edit. Everything it proposes is verified by the same engineering checks.
Plain language · attached documents · reviewable edit operations
Fault detection and verification
50 kinds of finding across electrical, PLC, network and machine-safety rules, each on the part it concerns with the rule behind it. Change, re-check, repeat.
Checks cover defined rules only, and verification scope varies by rule and configuration. Not a certification or a claim of full compliance.
Electrical · PLC · network · machine safety
PLC engineering
Rack, addresses, I/O list and tags come from the same design, so the PLC project starts where the schematic ends. Tag tables for Siemens TIA Portal, Rockwell Studio 5000, IEC 61131-3 (Codesys, TwinCAT), Schneider Electric, Omron Sysmac / CX-Programmer, Mitsubishi GX Works.
PLC logic generated from the design: In development with design partners
Rack · addresses · I/O list · six tag-table formats
Documentation
The PDF drawing set, BOM, wire list, terminal plan and cable list all come from the same model, so they always agree.
PDF · XLSX · CSV
Built on the standards you already work to.
Symbols, sheets, designations and checks follow the IEC and ISO conventions of the trade.
| Standard | Used for |
|---|---|
| IEC 60617 | Graphical symbols on every sheet |
| IEC 61082-1 | Sheet frame, current-path columns and page.column cross-references |
| IEC 81346 | Reference designations: =function +location -tag |
| EN ISO 7200 | Title blocks |
| IEC 60445 · IEC 60757 | Conductor colours and colour codes on wires |
| IEC 61131-3 | PLC tag names, data types and the generic tag table |
| Standard | Used for |
|---|---|
| IEC 60204-1 | Main switch, protection, motor overload, protective earth, emergency stop, interlocks, coil switching and wire colours |
| ISO 13850 | Emergency stop wired in hardware |
| IEC 60364-5-54 | Protective conductor cross-sections |
| IEC 60364-5-52 | Wire cross-section against the protective device |
| IEC 61140 | Which equipment needs protective earth |
For the panels and machines you build.
| Application | What the engine checks there | Example project in the editor |
|---|---|---|
| Industrial control panels | Main switch, protection, PE sizes, terminal fill | Every example project |
| Motor control systems | Interlocks, overloads, coil voltages, wire colours | DOL starter conveyor M17 pages · 9 devicesStar-delta pump P12 pages · 9 devices |
| Conveyor systems | PLC inputs, PNP/NPN, a hardwired emergency stop | Conveyor drive M1 — PLC controlled DOL starter11 pages · 16 devices |
| Machine automation | Rack slots, addresses, tag names per vendor | Conveyor 3 PLC6 pages · 10 devicesMixer 2 PLC2 pages · 5 devices |
| Process automation | Analog signal ranges between devices and PLC channels | No example project yet |
| Networked machine cells | IP addresses, PROFINET names, EtherCAT port order | Packaging cell PROFINET3 pages · 5 devicesAssembly line EtherCAT2 pages · 3 devices |
| Repetitive machine designs | The same checks on every variant of one readable project file | Every example project |
Help shape the future of electrical engineering.
Designstrom is collaborating with a select group of teams who design and build electrical systems:
Who we work with
- Industrial automation system integrators
- Electrical panel builders
- Machine manufacturers and OEMs
- Electrical engineering teams
Design partners receive
- Early access to the product
- Direct collaboration with the founder
- Implementation and onboarding support
- The opportunity to influence the product roadmap
- Validation on your real engineering workflows

Built by someone who understands both sides of engineering.
Aradhya Saxena spent 3.5 years as a system integration engineer (industrial automation, schematics, machine systems), then 5 years in software and agentic AI. Designstrom is the tool he wanted on the shop floor.
LinkedIn · Aradhya SaxenaQuestions engineers ask.
Does Designstrom replace my CAD tool?
Designstrom is a model-first workspace for schematic design. Start with new projects or variants, side by side with the tools you use today.
Does the AI decide whether a design is correct?
The Designstrom engine checks the design deterministically. The AI reviews the layout, proposes and edits, and the engineer approves.
What does a passing check mean for my design?
Checks cover defined rules and standards, which makes your design review-ready.
Which standards do you use?
IEC 60617 symbols, and rule checks drawn from IEC 60204-1, ISO 13850, IEC 60364-5-54 and IEC 61140. PLC tag naming follows IEC 61131-3.
Which PLC platforms can I export tag tables for?
Siemens TIA Portal, Rockwell Studio 5000, IEC 61131-3 (CODESYS, TwinCAT), Schneider Electric, Omron Sysmac / CX-Programmer and Mitsubishi GX Works.
Can it generate PLC logic?
PLC logic generation is in development with our design partners. Today Designstrom already builds the rack, addresses, I/O list and tag tables from your design.
Is it available in German?
Yes, the interface supports English and German.
What happens to my project data?
Your project data stays yours and is used only with your permission.
Your next design shouldn't start from scratch.